What is the latest version of MassLynx software for the Xevo G2-XS QTof and Xevo G2-XS Tof? - WKB9054
ENVIRONMENT
- MassLynx 4.2
- Xevo G2-XS QTof
- Xevo G2-XS Tof
- Microsoft Windows 11
- Microsoft Windows 10
For other instruments, see What is the latest version of MassLynx that supports my instrument?
ANSWER
| Latest Full Install Version | Release date | Windows Operating System Supported | Comments and supported EPCs |
| Xevo G2-XS Q-Tof only MassLynx 4.2 SCN 1051 | November 2025 | Windows 11 Enterprise LTSC 2024 (64-bit) [Waters Lenovo P5 6 Core only], Windows 10 Enterprise LTSC 2021 (64-bit) [Waters Lenovo P5 6 /12 core, and P520 /P720 only], Windows 10 Enterprise LTSB 1607 |
Xevo G2-XS Q-Tof only |
|
Xevo G2-XS Q-Tof and Xevo G2-XS Tof |
March 2022 | Windows 10 Enterprise LTSC 2021 (64-bit), [WatersLenovo P5 6 /12 core, and P520 /P720 only]*, Windows 10 Enterprise LTSB 1607 |
*Note: The release notes have not been updated to reflect the new Windows version and PCs supported |
Always read the Software Change Note Release Notes before installing MassLynx software to ensure that it is compatible with your overall system.
ADDITIONAL INFORMATION
Also see How to request a MassLynx software upgrade.
| Previous Full Install Versions | Release date | Patch | Windows Operating System Supported | |
| Xevo G2-XS Q-Tof only MassLynx 4.2 SCN 1050 | June 2025 | Windows 11 Enterprise LTSC 2024 (64-bit) [Waters Lenovo P5 6 Core only], Windows 10 Enterprise LTSC 2021 (64-bit) [Waters Lenovo P5 6 /12 core, and P520 /P720 only], Windows 10 Enterprise LTSB 1607 |
New: support for Windows 11 Xevo G2-XS Q-Tof only |
|
| March 2022 | Windows 10 Enterprise LTSC 2021 (64-bit), [Waters Lenovo P5 6 /12 core and P520 / P720 only]*, Windows 10 Enterprise LTSB 1607 |
*Note: The release notes have not been updated to reflect the new Windows version and PCs supported | ||
|
Xevo G2-XS Q-Tof - MassLynx 4.2 SCN 1018 |
August 2020 |
SCN 1033 (667006591) |
Windows 10 Enterprise LTSB 1607 Windows 7 Professional 64 Bit, Service Pack 1 |
Note: Q-Tof support ONLY |
|
Xevo G2-XS Tof - MassLynx 4.2 SCN 1027 |
April 2021 | - | Windows 10 Enterprise LTSB 1607 Windows 7 Professional 64 Bit, Service Pack 1 |
New EPC and new ADC Note: Tof support ONLY |
| MassLynx 4.2 SCN 996 | March 2020 | - | Windows 10 Enterprise LTSB 1607 Windows 7 Professional 64 Bit, Service Pack 1 |
|
December 2018 |
SCN 1010 |
Windows 10 Enterprise LTSB 1607 Windows 7 Professional 64 Bit, Service Pack 1 |
New: UniSpray Supported | |
| MassLynx 4.1 SCN 949 | February 2017 | - | Windows 7 Professional 64 Bit, Service Pack 1 | |
| MassLynx 4.1 SCN 958 | January 2016 | SCN 967 mandatory | Windows 7 Professional 64 Bit, Service Pack 1 | |
| MassLynx 4.1 SCN 937 | August 2015 | - | Windows 7 Professional 64 Bit, Service Pack 1 | |
| MassLynx 4.1 SCN 939 | April 2015 | - | Windows 7 Professional 64 Bit, Service Pack 1 | |
| MassLynx 4.1 SCN 923 | June 2014 | - | Windows 7 Professional 64 Bit, Service Pack 1 |
Note - Although the release notes for SCN 1018 indicate that it supports both Q-tof and tof variants of Xevo G2-XS, an issue has been identified that means SCN 1018 will not support the Xevo G2-XS tof.
NOTE : MassLynx 4.2 SCN 996 was created to support future EPC and ADC hardware on YFC and later serial numbers. SCN996 incorporates the Lenovo P510 compatibility fix from patch SCN1010. For existing systems, regardless if the relevant hardware has been upgraded or not, upgrade from MassLynx 4.2 SCN966 + SCN1010 to SCN996 for ease of future compatibility of the boards.