What is the latest version of MassLynx that supports an SQD2? - WKB422

Article number: 422

ENVIRONMENT

  • MassLynx 4.2
  • SQ Detector 2
  • Microsoft Windows 11
  • Microsoft Windows 10

For other instruments, see What is the latest version of MassLynx that supports my instrument?

ANSWER

Latest Full Install Version Release Date Patch Windows Operating System Supported Comments and supported EPCs
MassLynx 4.2 SCN 1051
November 2025 - Windows 11 Enterprise LTSC 2024 (64-bit) [Waters Lenovo P5 6 Core only],
Windows 10 Enterprise LTSC 2021 (64-bit) [Waters Lenovo P5 6 core, P5 12 Core and P520 only],
Windows 10 Enterprise LTSB 1607
New Adlink ApolloLake EPC (700013715) and Adlink EPCs (700005817, 700011089)*

*Note: Instruments with serial number LCB ship with Adlink EPCs (2023-2024), ApolloLake EPCs will ship with Serial number LCC

Before you install MassLynx software always read the release notes to ensure that the software is compatible with your overall system.

Click links for release notes.

ADDITIONAL INFORMATION

Also see How to request a Masslynx software upgrade.

Previous Full Install Versions Release Date Patches Windows Operating System Supported Comments and supported EPCs
MassLynx 4.2 SCN 1050
June 2025 - Windows 11 Enterprise LTSC 2024 (64-bit) [Waters Lenovo P5 6 Core only],
Windows 10 Enterprise LTSC 2021 (64-bit) [Waters Lenovo P5 6 core, P5 12 Core and P520 only],
Windows 10 Enterprise LTSB 1607
New: support for Evosep One LC and  Windows 11
New Adlink ApolloLake EPC (700013715) and Adlink EPCs (700005817, 700011089)*
MassLynx 4.2 SCN 1048 July 2024 - Windows 10 Enterprise LTSC 2021 (64-bit), [Waters Lenovo P520 only],
Windows 10 Enterprise LTSB 1607
New Adlink ApolloLake EPC (700013715) and Adlink EPCs (700005817, 700011089)*
MassLynx 4.2 SCN 1046 March 2024 - Windows 10 Enterprise LTSC 2021 (64-bit), [Waters Lenovo P520 only],
Windows 10 Enterprise LTSB 1607
New Adlink ApolloLake EPC (700013715) and Adlink EPCs (700005817, 700011089)*
MassLynx 4.2 SCN 1045 July 2023 - Windows 10 Enterprise LTSC 2021 (64-bit), [Waters Lenovo P520 only],
Windows 10 Enterprise LTSB 1607
New Adlink ApolloLake EPC (700013715) and Adlink EPCs (700005817, 700011089)*
For preparative systems:
MassLynx 4.2 SCN 1037
September 2021 - Windows 10 Enterprise LTSB 1607 Adlink EPCs (700005817, 700011089) Note*
3767 Autosampler Supported.
MassLynx 4.2 SCN 1043 February 2023 - Windows 10 Enterprise LTSC 2021 (64-bit), [Waters Lenovo P520 only],
Windows 10 Enterprise LTSB 1607
New Adlink ApolloLake EPC (700013715) and Adlink EPCs (700005817, 700011089)
MassLynx 4.2 SCN 1042 December 2022 - Windows 10 Enterprise LTSB 1607 New Adlink ApolloLake EPC (700013715)
Adlink EPCs (700005817, 700011089)
MassLynx 4.2 SCN 1040 August 2022 - Windows 10 Enterprise LTSB 1607 Adlink EPCs (700005817 and 700011089)
MassLynx 4.2 SCN 1035 March 2022 - Windows 10 Enterprise LTSB 1607 The original Adlink EPC (700005817)
The new variant of Adlink EPC (700011089)
MassLynx 4.2 SCN 985 revision B
Note: only use SCN 985 revision B 
Q2 2019 - Windows 10 Enterprise LTSB 1607
Windows 7 Professional 64 Bit, Service Pack 1
For preparative systems:
MassLynx 4.2 SCN 1011
July 2021 - Windows 10 Enterprise LTSB 1607 3767 Autosampler Support added
SCN withdrawn replaced by SCN 107
MassLynx 4.2 SCN 984 October 2017 - Windows 10 Enterprise LTSB 1607
Windows 7 Professional 64 Bit, Service Pack 1
UniSpray Support added
MassLynx 4.1 SCN 962 February 2017 - Windows 7 Professional 64 Bit, Service Pack 1 Supports the new Kontron Embedded PC SAP 700011089 and the earlier Embedded PC (Adlink M946 EPC) SAP 700005817
MassLynx 4.1 SCN 930 January 2015 SCN 953 Windows 7 Professional 64 Bit, Service Pack 1 Supports the original Embedded PC (Adlink M946 EPC) SAP 700005817
MassLynx 4.1 SCN 918 April 2014 none Windows 7 Professional 64 Bit, Service Pack 1 Supports the original Embedded PC (Adlink M946 EPC) SAP 700005817
MassLynx 4.1 SCN 855 April 2012 SCN 914 Windows 7 Professional 64 Bit, Service Pack 1 Supports the original Embedded PC (Adlink M946 EPC) SAP 700005817

Not able to find a solution? Click here to request help.