What are the part numbers and lengths of vacuum tubing available for MS systems? - WKB54326
ENVIRONMENT
- SYNAPT G2-S MS/HDMS
- SYNAPT G2-S
- Vion IMS QTof
- Xevo TQ-S
- Xevo TQ-XS
- Xevo TQ Absolute
- Xevo G3
- cyclic IMS
- MRT
- Xevo MRT
- SYNAPT XS
- Xevo TQ Absolute XR
ANSWER
|
Instrument |
Backing System |
Backing Line |
|
SYNAPT G2-S |
Leybold Rotary Pump SOGEVAC |
700006012 (Vacuum Hose, 38mm x 1m) - VAC HOSE ASSEMBLY |
|
M940714CC1-S (Vacuum Hose, 25mm x 1m) - VAC HOSE ASSY (PAIR) |
||
|
Edwards Scroll Pumps |
700006012 (Vacuum Hose, 38mm x 1m) - VAC HOSE ASSEMBLY |
|
|
M940714CC1-S (Vacuum Hose, 25mm x 1m) - VAC HOSE ASSY (PAIR) |
||
|
205001227 (2 x KF40 3m) - EXTENDED BACKING HOSE KIT KF40 3m |
||
|
Ebara EV-SA20 (2017 onward) |
700011391 = 1.5M NW40 BACKING LINE WITH PUMP CONTROL 700011460 = 3M NW40 BACKING LINE WITH PUMP CONTROL |
|
|
205001227 - Extended 3.0 m backing line (2 x KF40 3m) - EXTENDED BACKING HOSE KIT KF40 3m |
||
|
SYNAPT G2-Si |
Leybold Rotary Pump SOGEVAC |
700006012 (Vacuum Hose, 38mm x 1m) - VAC HOSE ASSEMBLY |
|
M940714CC1-S (Vacuum Hose, 25mm x 1m) - VAC HOSE ASSY (PAIR) |
||
|
Edwards Scroll Pump |
700006012 (Vacuum Hose, 38mm x 1m) - VAC HOSE ASSEMBLY |
|
|
205001227 (2 x KF40 3m) - EXTENDED BACKING HOSE KIT KF40 3m |
||
|
M940714CC1-S (Vacuum Hose, 25mm x 1m) - VAC HOSE ASSY (PAIR) |
||
|
Ebara EV-SA20 (2017 onwards) |
700011391 - 1.5M NW40 BACKING LINE WITH PUMP CONTROL 700011460 Extended 3.0 m backing line - 3M NW40 BACKING LINE WITH PUMP CONTROL |
|
|
205001227 (2 x KF40 3m) - EXTENDED BACKING HOSE KIT KF40 3m |
||
|
Vion |
Ebara EV-SA20 |
700011414 = Extended 3.0 m backing line |
|
700011461 = 3M NW40 BACKING LINE WITH PUMP CONTROL |
||
| 700010797 Backing pump cable 1.5m | ||
|
Xevo TQ-S |
Leybold SV65Bi/FC Rotary Pump SOGEVAC |
700009157 - HOSE ASSEMBLY NW40 FITTINGS 1.5 MTR LONG 205001227 (2 x KF40 3m) - EXTENDED BACKING HOSE KIT KF40 3m |
|
Edwards Scroll Pumps |
700009157 - HOSE ASSEMBLY NW40 FITTINGS 1.5 MTR LONG 205001227 - EXTENDED BACKING HOSE KIT KF40 3m (2 x KF40 3m) |
|
|
Ebara EV-SA20 |
289011700/700011264 1.5 m backing line NW40 - 1.5M NW40 BACKING LINE WITH PUMP CONTROL |
|
|
700011268 3M NW40 BACKING LINE WITH PUMP CONTROL |
||
|
Xevo TQ-XS |
Ebara EV-SA30 |
289011700/700011264 1.5m backing line - 1.5M NW40 BACKING LINE WITH PUMP CONTROL |
|
700011268 = 3M NW40 BACKING LINE WITH PUMP CONTROL |
||
| Xevo TQ Absolute | Ebara EV-SA30 | 441002807/700013609 Backing pump cable |
| Xevo TQ Absolute XR | Ebara EV-SA30 | 441002807/700013609 Backing pump cable |
| Xevo G3 | Ebara EV-SA20 | 441001496/700010797 Backing pump cable |
| Edwards nXR120i | 700013832 Backing pump cable | |
SELECT SERIES MRT System/SELECT SERIES Cyclic IMS |
Ebara EV-SA30 |
441001889 Backing pump cable 700011391 including the backing line
|
| Xevo MRT | Ebara EV-SA20 | |
| SYNAPT XS | Ebara EV-SA30 | 289011828/700011391 Backing pump cable |
| Edwards NXL200i | 441002810/700013593 backing pump cable | |
ADDITIONAL INFORMATION