What are the Thermo CDS instrument compatibilities with Waters Driver Pack 2022 Release 1? - WKB228889
ENVIRONMENT
- ACQUITY Arc
- ACQUITY UPLC
- ACQUITY UPLC H-Class
- ACQUITY UPLC H-Class Bio
- ACQUITY UPLC I-Class
- ACQUITY UPLC H-Class PLUS
- ACQUITY UPLC H-Class PLUS Bio
- ACQUITY UPLC I-Class PLUS
- ACQUITY UPLC M-Class
- nanoACQUITY UPLC
- ACQUITY Premier
- Arc HPLC
- Arc Premier
ANSWER
Thermo CDS Instrument Compatibility with DP 2022 R1 |
|||||||
---|---|---|---|---|---|---|---|
Configuration |
System |
Detectors /Sample Organizer |
Chromeleon v7.3 | Chromeleon v7.2.10 Mud | Xcalibur 4.4 SII v1.6 | Xcalibur Current LC Devices v3.2 SP3 | |
Part Numbers for Thermo Licenses (purchased from Waters) | 7200.1003 + 7350.0107 | 7200.1003 + 7050.0107 | 7200.0078 | 7200.0078 | |||
ACQUITY UPLC Systems (18,000 psi) |
BSM/FTN (Single column heater support) |
ACQUITY I-Class* |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
No
|
BSM/FTN/CM - (Multi column manager support) |
ACQUITY I-Class+ |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
No
|
|
BSM/FL (Single column heater support) |
ACQUITY I-Class+ |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
Compatible
|
|
BSM/FL/CM (Multi column manager support) |
ACQUITY I-Class+ |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
Compatible
|
|
BSM/BSM/FTN/CM |
ACQUITY UPLC I-Class + 2D |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
In development
|
In development
|
In development
|
No
|
|
BSM/BSM/FL/CM |
ACQUITY UPLC I-Class + 2D |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
In development
|
In development
|
In development
|
No
|
|
ACQUITY UPLC Systems (15,000 psi) |
BSM/FTN (Single column heater support) |
ACQUITY Premier, ACQUITY H-Class Binary (SS/Bio) |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
No
|
BSM/FTN/CM - (Multi column manager support) |
ACQUITY Premier, ACQUITY H-Class Binary (SS/Bio) |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
No
|
|
QSM/FTN (Single column heater support) |
ACQUITY Premier, ACQUITY H-Class Binary (SS/Bio) |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
No
|
|
QSM/FTN/CM (Multi column manager support) |
ACQUITY Premier, ACQUITY H-Class Binary (SS/Bio) |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
Yes
|
Yes
|
Yes
|
No
|
|
BSM/BSM/FTN/CM |
ACQUITY Premier, ACQUITY H-Class Binary (SS/Bio) - 2D |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO |
In development
|
In development
|
In development
|
No
|
|
BSM/QSM/FTN/CM |
ACQUITY Premier, ACQUITY H-Class Binary (SS/Bio) - 2D |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO
|
Compatible
|
Compatible
|
Compatible
|
No
|
|
LegacyACQUITY UPLC Systems (15,000 psi) |
BSM/FL (Single column heater support) |
ACQUITY UPLC* (Limited Support) |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO
|
Yes
|
Yes
|
Yes
|
Yes
|
BSM/FL (Multi column manager support) |
ACQUITY UPLC* (Limited Support) |
TUV, PDA, eLambda PDA, PDA TS, FLR, ELSD, RI, SO
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Microscale UPLC Systems |
uBSM/uFL (Direct Inject) |
ACQUITY M-Class |
TUV, PDA, eLambda PDA, SO |
In development |
In development |
In development
|
Yes
|
uBSM/uFL/TVM (single pump trapping) |
ACQUITY M-Class |
TUV, PDA, eLambda PDA, SO |
In development |
In development
|
In development
|
Yes
|
|
uBSM/ASM/uFL/TVM (dual pump trapping) |
ACQUITY M-Class |
TUV, PDA, eLambda PDA, SO |
In development
|
In development
|
In development
|
Yes
|
|
2 x uBSM /uFL/TVM (dual pump trapping) |
ACQUITY M-Class |
TUV, PDA, eLambda PDA, SO |
In development
|
In development
|
In development
|
No
|
|
Legacy Microscale UPLC Systems |
uBSM/uFL (Direct Inject) |
nanoACQUITY (Limited Support) |
TUV, PDA, eLambda PDA |
No
|
No
|
In development
|
Yes
|
uBSM/uFL/TVM (single pump trapping) |
nanoACQUITY (Limited Support) |
TUV, PDA, eLambda PDA |
No
|
No
|
In development
|
Yes
|
|
uBSM/ASM/uFL/TVM (dual pump trapping) |
nanoACQUITY (Limited Support) |
TUV, PDA, eLambda PDA |
No
|
No
|
In development
|
Yes
|
|
2 x uBSM /uFL/TVM (dual pump trapping) |
nanoACQUITY (Limited Support) |
TUV, PDA, eLambda PDA |
No
|
No
|
In development
|
No
|
|
|
|
|
|
|
|
|
|
UHPLC Systems |
BSM-R/FTN-R (Single column heater support) |
Arc Premier |
2489, 2998, 2475, 2424, 2414, SO |
In development
|
In development
|
No
|
No
|
BSM-R/FTN-R/ CM or CM-30S (Multi column manager support) |
Arc Premier |
2489, 2998, 2475, 2424, 2414, SO |
In development
|
In development
|
No
|
No
|
|
QSM-R/FTN-R (Single column heater support) |
Arc Premier, ACQUITY Arc (SS & Bio), Arc HPLC |
2489, 2998, 2475, 2424, 2414, SO |
Yes
|
Yes
|
No
|
No
|
|
QSM-R/FTN-R/CM or CM-30S (Multi column manager support) |
ACQUITY Arc (SS & Bio), Arc HPLC |
2489, 2998, 2475, 2424, 2414, SO |
Yes
|
Yes
|
No
|
No
|
|
HPLC Systems |
QSM-R/FTN-R (Single column heater support) |
Arc HPLC |
2489, 2998, 2475, 2424, 2414, SO |
Yes
|
Yes
|
No |
No |
QSM-R/FTN-R/CM/CM-30S (Multi column manager support) |
Arc HPLC |
2489, 2998, 2475, 2424, 2414, SO |
Yes
|
Yes
|
No |
No |
|
Definitions |
I-Class means PLUS and earlier versions H-Class means PLUS and earlier versions In development - Third-party vendor has agreed to support, but development is not complete Compatible - Expected to work, but not tested Yes - Supported, by evaluation or formally risk-assessed for support No - No formal evaluation or formal risk assessment for support |
Unlisted systems imply outside acquisition control agreement. Systems and their accessories, such as ACQUITY UPC2, APC, PATROL, and Preparative LC, are typically excluded.
ADDITIONAL INFORMATION
id228889, UPAQSM, UPARBQSM, UPARBSMFTN, UPARCH30, UPARHQSM, UPARQSM, UPARSMFTN, UPBSMIVD, UPIBSM, UPIBSM+, UPIBSMIVD, UPISMFL, UPISMFL+, UPISMFTIVD, UPISMFTN, UPISMFTN+, UPLCCOLHTR, UPMASM, UPMBSM, UPMSMFL, UPNAYXPMP, UPNBINARY, UPNSAMMGR, UPNSOLMGR, UPPDAARCB, UPQSM, UPQSM+, UPQSMBIO, UPQSMBIO+, UPSMFTN, UPSMFTN+, UPSMFTNB+, UPSMFTNBIO, UPSMIVD, UPSMPMGR