How to update the server name in the NuGenesis SDMS Administrator list on login - WKB26376
Article number: 26376
OBJECTIVE or GOAL
Update the NuGenesis Server name list after entering the wrong server name.
ENVIRONMENT
- NuGenesis 8 SDMS
PROCEDURE
- Close the NuGenesis 8 login screen.
- Open the Drive:\Program Files (x86)\NuGenesis 8.0\database folder.
- Delete the NGLocalProjectList.xml file.
- Log in to SDMS Administrator.
- Do not update the local list.
- Add the new server in SDMS Administrator.
ADDITIONAL INFORMATION
The wrong server was added in NuGenesis System Administrator.
The server was deleted in SDMS Administrator.
Open SDMS Administrator to log in, server name displayed is the server deleted.
SDMS Administrator server name list is stored in NGLocalProjectList.xml. The file is located on the drive where NuGenesis 8 is installed (NuGenesis 8.0\database folder).