What licenses are required to bring a Perkin Elmer system online in Empower? - WKB99214

Article number: 99214

ENVIRONMENT

  • Perkin Elmer LC or GC
  • Empower 3

ANSWER

NOTE: The information below is only for the Empower licensing structure. Do NOT refer to this for Instrument support under the Empower version. Refer to Perkin Elmer's GC /LC release notes to confirm the minimum Empower version supported for the Instrument models.

Perkin GC Instruments

Perkin Instruments Model / Type Empower Version Instrument Type Driver Version Instrument Catalog Version License Enforced? Licenses Required
Perkin GC 2400 Empower 3.7.0 PKIGC Agilent ICF SL 3.7.01 and above
installed with the Perkin ICF GC driver.
Version 3 Yes Empower System Control and Perkin GC License
Version 2 No

Empower System Control and Perkin GC License*

Recommended v3 Catalog

Version 1 No Not Supported.
 < Empower 3.7.0 PKIGC Agilent ICF SL 3.7.01 and above
installed with the Perkin ICF GC driver.
NA No Empower System Control and Perkin GC License*
Clarus 580
Clarus 590
Clarus 680
Clarus 690
Empower 3.7.0 Clarus 580
Clarus 590
Clarus 680
Clarus 690
Legacy Perkin Elmer GC Driver.
Note: Does not require Agilent ICF Support Layer
Version 3 Yes Empower System Control and Perkin GC License*
Version 2 No Empower System Control and Perkin GC License*
Version 1 No Empower System Control and Perkin GC License*
 < Empower 3.7.0 Clarus 580
Clarus 590
Clarus 680
Clarus 690
NA No Empower System Control and Perkin GC License*
HS 40
HS 110
≥ Empower 3.7.0 HS 40
HS 110
Legacy Perkin Elmer HS Driver
Note: Does not require Agilent ICF Support Layer
Version 3
Version 2
Version 1
No Not Required
 < Empower 3.7.0 NA No Not Required

* Paper-based GC License, un-enforced

Perkin LC Instruments

 

Perkin Instruments Model / Type Empower Version Instrument Type Driver Version Instrument Catalog Version License Enforced? Licenses Required
Perkin LC 300 Empower 3.7.0 PKILC Agilent ICF SL 3.7.01 and above
installed with the Perkin ICF LC driver
Version 3 Yes Empower System Control and Perkin LC License
Version 2 No Empower System Control and Perkin LC License**
Version 1 No Not Supported.
Empower 3.7.0 AgLC Agilent ICF SL 3.5 and till ICF SL 3.6.1
installed with the Perkin ICF LC driver
Version 3 Yes Empower System Control and Agilent LC License
Version 2 Yes Empower System Control and Agilent LC License
Version 1 Yes Empower System Control and Agilent LC License
 < Empower 3.7.0 PKILC Agilent ICF SL 3.7.01 and above
installed with the Perkin ICF LC driver
NA No Empower System Control and Perkin LC License**
 < Empower 3.7.0 AgLC Agilent ICF SL 3.5 and till ICF SL 3.6.1
installed with the Perkin ICF LC driver
NA Yes Empower System Control License and Agilent LC license
Perkin Flexar LC Instruments Empower 3.7.0 FLX-Pump
FLX-UV
FLX-PDA
FLX-CO
FLX-AS
Legacy Perkin Elmer LC Driver.
Note: Not supported in ICF-based control
Version 3 Yes Empower System Control and Perkin LC License**
Version 2 No Empower System Control and Perkin LC License**
Version 1 No Empower System Control and Perkin LC License**
 < Empower 3.7.0 FLX-Pump
FLX-UV
FLX-PDA
FLX-CO
FLX-AS
NA No Empower System Control and Perkin LC License**

 

** Paper-based LC License, un-enforced