How to configure a data channel port range for an FTP site in Microsoft IIS - WKB63117
Article number: 63117
OBJECTIVE or GOAL
Set a range of port numbers for an FTP server to use when establishing passive-mode FTP connections.
ENVIRONMENT
- NuGenesis 8 or 9 SDMS with Managed Storage locations
PROCEDURE
- Configure the FTP site:
- Open IIS Manager.
- Select the server name.
- Double-click on FTP Firewall Support.
- Specify a range of numbers (for example, 3000-3500) in the Data channel Port Range box and click Apply.
- Restart the Microsoft FTP service.
- Configure the Windows Firewall:
- Open Control Panel > Administrative Tools > Windows Firewall with Advanced Security.
- Click Inbound Rules.
- Click New rule.
- Choose the rule type "Port" and click Next.
- On the Protocols and Ports page, select TCP, and specify the same port range given in the IIS configuration.
- Specify a name for the rule and click Finish.