Where can I find a list of devices that have been tested with the Waters Serial Device Support software? - WKB57949

Article number: 57949

ENVIRONMENT

  • NuGenesis 9
  • NuGenesis 8
  • Waters Serial Device Support (SDS) 2.0

ANSWER

The following table lists the instruments which have been tested by Waters for compatibility with SDS.  If an instrument is not in this list, it does not mean that it is incompatible, only that the specific model has not been tested.  For an instrument to be compatible with SDS, it needs either an RS-232 serial port or a USB port with a USB-to-RS232 adapter.  Such adapters are usually provided by the instrument manufacturer.  Waters does not provide, nor recommend, any generic USB-to-serial adapters.

Manufacturer/Vendor Model Name/Number Device Type Compatiblewith SDS? Comments
Accumet AB15 pH meter YES If using Passive mode with this meter, configure the meter to print only the currently displayed data, not the stored data.
Accumet AR15 pH meter YES Requires firmware v1.04 or later for SDS Active mode

Advanced Instruments

2020

Osmometer

YES

Works only in Passive mode. Does not need manufacturer’s cable. Later firmware versions have a “LIMS Mode”, which is optimal for Waters SDS.

Agilent

708-DS

Dissolution test machine

NO

It cannot output data.

AND

HR-202

Balance

YES

 

AND

GR-202

Balance

YES

 

Arkray

OM-6060

Osmometer

YES

It is not possible to obtain the Calibration Date.

Atago Rx Digital Refractometer Yes works also Bidirectional

BUCHI

M-565

Melting-point apparatus

NO

It cannot output data.

Copley Scientific

TPK 2000

Flow controller

YES

 

KONICA MINOLTA

CM-5

Color difference meter

NO

It sends to each row a command of <CR><LF>.

Decagon Devices

AquaLab 4TEV DUO

Water activity equipment

YES

 

DKK-TOA

HM-60G

pH meter

YES

 

Elga 

Purelab Ultra

Water purity

YES

 

Gonotec

Osmomat 030

Osmometer

YES

Instrument operation is very important. It can obtain the value with correct operation on the instrument.

Heraeus

Multifuge 3

Centrifuge

NO

It is not possible to use the Heraeus Multifuge 3 centrifuge with SDS. The instrument only sends a continuous data stream through the port.

Hiranuma Sangyo

AQV-2200A

Karl Fischer moisture titrate

YES

 

Hiranuma Sangyo

AQV-2100

Karl Fischer moisture titrate

YES

 

Hiranuma Sangyo

COM-1700S

Potentiometric titrator

YES

It is not possible to output the chart.

Horiba

DS-72

Conductivity

YES

 

Horiba

F52

pH meter

YES

 

Horiba

F55

pH meter

YES

This device has two channels. In order to get data from both channels, you must create two SDS configuration files. The manufacturer’s cable is not required.

Horiba

F74

pH meter

YES

 

Horiba

F71S

pH meter

YES

 

Kyoto Electronics

DA-130N

Density/specific gravity meter

YES

 

Kyoto Electronics

AMKA-510

Karl Fischer moisture titrate

NO

It sends to each row a command of <CR><LF>.

Metrohm

737KF

Coulometer

YES

 

Metrohm

756KF

Coulometer

YES

 

Metrohm

780

pH meter

YES

 

Metrohm

784KFP

Titrator

YES

Requires a Null Modem cable or adapter in order to connect to a PC or Tibbo server.

Metrohm

KF Titrino 701

Titrator

YES

Requires a Null Modem cable or adapter in order to connect to a PC or Tibbo server.

Mettler Toledo

204-S

Balance

YES

 

Mettler Toledo

AB204-S

Balance

YES

 

Mettler Toledo

AB54-S

Balance

YES

 

Mettler Toledo

AE-118DR

Balance

YES

 

Mettler Toledo

AG204DR

Balance

YES

Dedicated connection cable. It is possible to use only in Active mode.

Mettler Toledo

AL204

Balance

YES

 

Mettler Toledo

AT200

Balance

YES

 

Mettler Toledo

AT-261 Delta Range

Balance

YES

Requires a Mini Mettler cable from Mettler Toledo.

Mettler Toledo

AX205

Balance

YES

 

Mettler Toledo

AX205DR

Balance

YES

 

Mettler Toledo

AX26

Balance

YES

 

Mettler Toledo

HR73

Moisture analyzer

YES

Requires a special cable from the manufacturer in order to connect to a PC.

Mettler Toledo

HR83-P

Moisture analyzer

NO

Dedicated connection cable. It needs specific software from Mettler Toledo to output data.

Mettler Toledo

ME 4002

Balance

YES

 

Mettler Toledo

MX5

Balance

YES

 

Mettler Toledo

MS1602S

Balance

YES

 

Mettler Toledo

PB303-S

Balance

YES

 

Mettler Toledo

PB5001-S

Balance

YES

 

Mettler Toledo

PG2002-S

Balance

YES

 

Mettler Toledo

PL202-S

Balance

YES

 

Mettler Toledo

PL601-S

Balance

YES

 

Mettler Toledo

PM30K

Balance

YES

 

Mettler Toledo

PM400

Balance

YES

 

Mettler Toledo

SevenMulti

pH meter

YES

 

Mettler Toledo

S20 SevenEasy

pH meter

YES

 

Mettler Toledo

XP204

Balance

YES

 

Mettler Toledo

XP205

Balance

YES

 

Mettler Toledo

XP4002

Balance

YES

 

Mettler Toledo

XP56

Balance

YES

 

Mettler Toledo

XP5003

Balance

YES

 

Mettler Toledo

XPE56Q

Balance

YES

 

Mettler Toledo

XS105

Balance

YES

 

Mettler Toledo

XS204

Balance

YES

 

Mettler Toledo

XS205

Balance

YES

 

Mettler Toledo

XSE205

Balance

YES

 

Mettler Toledo

XS-802S

Balance

YES

 

Mettler Toledo XSR Precision Balance YES Does not have an RS232 port.  Can communicate with SDS via Ethernet port. Requires MT-SICS Service active on it's Network interface.

Mettler Toledo Karl Fischer

DL38

Titrator

YES

 

Mitutoyo

293-411

Micrometer

YES

Dedicated connection cable

Mitutoyo

500-211

Vernier caliper

YES

Dedicated connection cable

NihonDenshoku

SE-2000

Spectrocolorimeter

YES

 

NihonDenshoku

SE-6000

Spectrocolorimeter

YES

 

OHaus

Adventurer AX 224 M

Balance

YES

 

OHaus

AV264CM

Balance

YES

 

OHaus

Discovery

Balance

YES

 

OHaus

Explorer

Balance

YES

 

OHaus

PA512 CM

Balance

YES

 

Okada Seiko

PC-30

Hardness meter

YES

 

Pharma Test

PTWS310

Dissolution test machine

NO

It cannot output data.

Randox Evolution Toxicology testing NO Requires acknowledgements from receiving device for RS232 connections.  SDS cannot send these acknowledgements.
Randox Evidence Toxicology testing NO Same issue as Randox Evolution.
Randox Investigator Toxicology testing NO Same issue as Randox Evolution.

RION

KL-04A

Light obscuration particle counter

YES

Dedicated USB-RS232c cable

Rudolph Research Analytical

AUTOPOLE5

Automatic polarimeter

NO

It sends to each row a command of <CR><LF>.

Sartorius

CPA224S

Balance

YES

 

Sartorius

CP225D

Balance

YES

Requires the DTR/DSR hardware flow control option in SDS. For direct RS232 connections, set DTR = “online”.in the SDS configuration .

Sartorius

ED224S

Balance

YES

 

Sartorius

ED6202S-CW

Balance

YES

 

Sartorius

CUBIS MSA225P

Balance

YES

 

Sartorius

CUBIS MSE224S-000-DU

Balance

YES

 

Sartorius

ME235P

Balance

YES

 

Sartorius

MSA125P-000-DI

Balance

YES

 

Sartorius

QUINTIX 1102-1S

Balance

YES

Dedicated miniA USB cable

Sartorius

QUINTIX 2102-1S

Balance

YES

Dedicated miniA USB cable

Sartorius

QUINTIX 213-1S

Balance

YES

Dedicated miniA USB cable

Sartorius

R200D

Balance

YES

 

Sartorius

SECURA224-1S

Balance

YES

 

Shimadzu

TXB422L

Balance

YES

 

Shimadzu

UW820S

Balance

YES

 

Shimadzu

UX2200H

Balance

YES

 

Thermo

Orion 2 Star

pH meter

YES

 

Thermo

Orion 3 Star

pH meter

YES

 

Thermo

Orion 370

pH meter

YES

 

Thermo

Orion 720 A+

pH meter

YES

 

Toki Sangyo

RE-80U

Viscometer

YES

 

Toki Sangyo

RE-85U

Viscometer

YES

 

Toki Sangyo

TVE-25H

Viscometer

YES

 

Toyama Sangyo

TK-362CPN

Disintegration test machine

YES

 