NuGenesis Smart Builder is installed but does not appear as a COM Add-in in Excel - WKB240488
Article number: 240488
SYMPTOMS
- NuGenesis Smart Builder is installed on a Windows PC
- No errors are present in the Smart Builder Auto IQ log
- Smart Builder is not loaded in Excel, and it does not appear in the COM Add-ins list or the Disabled Items list
- The "FormDesigner" registry key is present in HKLM\Software\Wow6432Node\Microsoft\Office\Excel\Addins and has LoadBehavior set to 3
ENVIRONMENT
- NuGenesis 9 LMS
- Office 365
CAUSE
Unknown; possible corruption in the Microsoft Office installation
FIX or WORKAROUND
- Perform an Online Repair of Microsoft Office:
- Open Control Panel > Programs and Features.
- Select Microsoft Office and click Change.
- Select Online Repair and click Repair.
- Restart when the repair is complete.
- Uninstall and reinstall Smart Builder.