Audit category Audit event Event description
Archive Device related events Delete File Data Device Deletion of an OSM device
Archive Device related events Modify File Data Device Modification of an OSM device's parameters
Archive Device related events Create File Data Device Creation of an OSM device
Archive Exception List related events Modify File Data Exception List Modification of the project exceptions list in an SDMS Archive Template
Archive Exception List related events Create File Data Exception List Creation of the project exceptions list in an SDMS Archive Template
Archive Template related events Create File Data Template Creation of an SDMS Archive Template
Archive Template related events Modify File Data Template Modification of an SDMS Archive Template
Archive Template related events Copy File Data Template Copying of an SDMS Archive Template
Archive Template related events Delete File Data Template Deletion of an SDMS Archive Template
Email Notification related events Notification Sent An email notification was sent by SDMS to one or more users.
Legal hold related events Create Legal Hold Creation of a Legal Hold policy in SDMS.
Legal hold related events Modify Legal Hold Modification of the Legal Hold policy parameters.
Legal hold related events Fix CRC related to Legal Hold Fix a corrupted database record via SDMS Administrator.
Legal hold related events Add Record to Legal Hold Add one or more records to a Legal Hold policy.
Legal hold related events Remove Record from Legal Hold Remove one or more records from a Legal Hold policy.
Legal hold related events Delete Legal Hold Deletion of a Legal Hold policy.
Notifier List related events Delete User in Notifier List A user was removed from the notification lists for Alert, Fatal, or DRS Status Project-level or Server-level events.
Notifier List related events Create User in Notifier List A user was added to the notification lists for Alert, Fatal, or DRS Status Project-level or Server-level events.
Policy related events Create Data Retention Policy Creation of an SDMS Data Retention policy.
Policy related events Fix CRC related to Policy Fix a corrupted record via SDMS Administrator.
Policy related events Modify Data Retention Policy Modification of an SDMS Data Retention Policy.
Privilege related events Revoke Privilege Remove privilege(s) from user(s).
Privilege related events Fix CRC related to privileges Fix a corrupted DB record via SDMS Administrator.
Privilege related events Grant Privilege Grant privilege(s) to user(s).
Project related events Rename Project Rename an SDMS Project.
Project related events Remove Project Removal of an SDMS Project.
Project related events Modify Managed Store Modification of the Managed Storage properties in an SDMS project.
Project related events Modify Tag Properties Modification of the metadata tag properties in an SDMS project.
Project related events Modify Project Properties Modification of SDMS project properties.
Project related events Add Project Restoration of a previously removed project.
Project related events Create Managed Store Adding an SDMS Managed Storage location to an SDMS project.
Project related events Delete Managed Store Removal of a SDMS Managed Storage location from a project.
Project related events Create Project Creation of an SDMS project.
Project related events Fix CRC related to project Fix a corrupted record via SDMS Administrator.
Reason related events Delete Restore Location Deletion of a Restore Location
Reason related events Modify Restore Location Modification of a Restore Location
Reason related events Create Restore Location Creation of a Restore Location
Reason related events Copy Reason Copy a Reason for Change
Reason related events Delete Reason Deletion of a Reason for Change
Reason related events Modify Reason Modification of a Reason for Change
Reason related events Create Reason Creation of a Reason for Change
Reason related events Copy Restore Location Copy a Restore Location between SDMS projects.
Report related events Delete Report Deletion of a record in an SDMS Print Data project.
Report related events Insert Report A record was added to an SDMS Print Data project.
Report related events Print Report A record was printed from an SDMS Print Data project.
Report related events View Attached File A file attachment on a record in an SDMS Print Data project was viewed.
Report related events Apply Template A UNIFY or Extraction template was applied to a record in an SDMS Print Data project.
Report related events Copy Report Copying a record within a or between to SDMS Print Data projects.
Report related events Insert Report by Template A user applies a UNIFY template to an existing record in an SDMS Print Data project.  The output of the template becomes a new record in the project.
Report related events Apply eSignature A user applies an eSignature to one or more SDMS print data records.
Report related events eSignature Attempt Failure A user entered an invalid password during an eSignature attempt.
Report related events Apply Annotation A user applied an annotation to an SDMS print data record.
Report related events Modify Tag Values A user modified the values in one or more modifiable metadata for an SDMS print data record.
Report related events Restore Report A File Data record was restored from SDMS to disk.
Report related events View Report A user views a Print Data report.
Report related events Reset DM Date Occurs when a user uses the Data Management Reset Utility to set the DM Candidacy date on archived files.
Script related events Create Script A user created a Script within SDMS Administrator's Script Builder.
Script related events Modify Script A script was modified via SDMS Administrator's Script Builder.
Script related events Delete Script A script was deleted.
Script related events Copy Script A script was copied between projects.
Search group related events Modify Search Group An SDMS Search Group was modified.
Search group related events Create Search Group An SDMS Search group was created.
Search group related events Delete Search Group An SDMS Search Group was deleted.
Server related events License Modified A user activates or deactivates licenses via SDMS Administrator.
Server related events Create Column Index A user crates an index on a metadata column via SDMS Administrator.
Server related events Modify Server A user edits a server name in the Master or Local Lists via SDMS Administrator.
Server related events Delete Server A server was removed from the Master or Local lists via SDMS Administrator.
Server related events Add Server A server was added to the Master or Local lists via SDMS Administrator.
Server related events Delete Location A NuGenesis RPC Service entry was removed from the Locations list via SDMS Administrator.
Server related events Delete Server Level Managed Store A user deletes a Managed Storage Location as defined in the SDMS database, via SDMS Administrator.
Server related events Add Location A NuGenesis RPC Service entry was added to the Locations list via SDMS Administrator.
Server related events Change ELN Data Location Configuration A user changed the LMS Database location in SDMS via SDMS Administrator.
Server related events Fix CRC Server Level Managed Store Fix a corrupted database record via SDMS Administrator.
Server related events Fix CRC related to server Fix a corrupted database record via SDMS Administrator.
Server related events Modify Server Level Managed Store A Managed Storage location definitions was modified via SDMS Administrator.
Server related events Create Server Level Managed Store A Managed Storage location was created via SDMS Administrator.
Server related events Modify Location A NuGenesis RPC Service entry was modified in the Locations list via SDMS Administrator.
Template related events Create Template An SDMS template (archive, UNIFY, or extraction) was created.
Template related events Copy Template An SDMS Template was copied between projects.
Template related events Delete Template An SDMS Template was deleted.
Template related events Modify Template An SMS Template was modified.
User related events User Password Set A user's Oracle logon password was set.
User related events Fix CRC related to users Fix a corrupted database record via SDMS Administrator.
User related events Create User An SDMS user account was created.
User related events Modify User An SDMS user account was modified.
User related events User Unlocked An SDMS user account was unlocked.
User related events User Authentication Failed A user failed to log in to SDMS.
User related events User Password Change A user changed their logon password.
User related events User Authenticated A user successfully logged in to SDMS.
User related events User Password Expired A user's password has expired.
User related events Delete User A user account was deleted.
UserGroup related events Fix CRC related to groups Fix a corrupted DB record via SDMS Administrator.
UserGroup related events Modify Group The properties for a user group in SDMS were modified.
UserGroup related events Remove Group Member One or more users were removed from an SDMS user group.
UserGroup related events Add Group Member On or more users were added to an SDMS user group.
UserGroup related events Delete Group An SDMS user group was deleted.
UserGroup related events Create Group An SDMS user group was created.
View related events Modify View A user modified a project view.
View related events Delete View A user deleted a project view.
View related events Copy View A user copied a project view to another project.
View related events Create View A user created a project view.
Volume Life Cycle related events Delete File Data Volume Obsolete, as the only OSM device type which supports deletion of volumes (Jukebox) is no longer supported.
Volume Life Cycle related events Modify File Data Volume Obsolete, for the same reasons as "Delete File Data Volume"
Volume Life Cycle related events Copy Volume Obsolete, for the same reasons as "Delete File Data Volume"
Volume Life Cycle related events Create File Data Volume A user created a volume for an offline device in the Service Configuration Console \ Offline Storage Manager.