How to configure logging of debug messages for Waters Storage Gateway and a Centera storage device - WKB21397
Article number: 21397
OBJECTIVE or GOAL
Configure logging of debug messages in Waters Storage Gateway and a Centera SDK.
ENVIRONMENT
- NuGenesis 8 SDMS
- Waters Storage Gateway 2.0 SP3
- A NuGenesis OSM device configured for Storage Gateway
- A DellEMC Centera storage device
PROCEDURE
For the Storage Gateway service:
- Browse to Drive:\StorageGateway\actback\backend\properties\com\creon\qdisr\properties.
- Open LoggingManager.properties in WordPad.
- Edit the line log4j.rootCategory=ERROR,CONSOLE,LOGFILE to log4j.rootCategory=DEBUG,CONSOLE,LOGFILE.
- Save and close the file.
- Restart the StorageGateway Job Manager service.
- The log file will be in Drive:\StorageGateway\actback\backend\bin\windows\manager.log.
For the Centera SDK on the Storage Gateway server:
- Open the Control Panel > System.
- Click Advanced system settings > Environment Variables.
- Set the following four variables:
- FP_LOGPATH=%TEMP%\CenteraSDKDebug.log
- FP_LOGFORMAT=TAB
- FP_LOGLEVEL=4
- FP_LOGKEEP=APPEND
- Restart the Storage Gateway services.