How to search and find data in Browse Projects (part 2) - Tip5

Article number: 49979

OBJECTIVE or GOAL

Find information in Browse Project using view filters.

ENVIRONMENT

  • Empower

PROCEDURE

  1. Click the Results tab in your Empower CDS project. Note that Filter By is set to Default.

  2. From the Filter By drop-down list, select Processed Today.

browse-proj2-1.png

The Results table displays one result, which was processed today.

browse-proj2-2.png

  1. To remove the view filter, click the Filter By drop-down list and select Default. The table now displays all of the results, as it did when we first opened the project.

browse-proj2-3.png

  1. Now let’s build a custom view filter to find a specific sample result by name. Click the Edit View tool.

browse-proj2-4.png

  1. In the View Filter editor, specify an operator of = and a value for the sample name in the SampleName field, in this case the name of the sample. The name is case-sensitive and must be typed exactly as it appeared originally. Save the view filter and exit the editor.

browse-proj2-5.png

The results table now displays results for the specified sample.

browse-proj2-6.png

Now let’s modify the view filter to display results for samples that have a common root name but are incremented by a number or letter.

  1. Click Edit View, remove the number at the end of the sample name and replace it with *. Save the change and exit the editor.

 

browse-proj2-7.png

This instructs Empower software to display results for any sample name that begins with “PQ Un”, regardless of what follows.

browse-proj2-8.png

The view filters we have described are static, meaning that every time you use the view filter only data meeting the set criteria will be displayed in the table.

What if you want to search for results for samples with different names? Rather than creating a series of static view filters, one for each sample, you can create one view filter that will help you find the results for multiple samples with different names. This is a dynamic or Just In Time view filter.

  1. In the view filter editor, remove the sample name and enter # as the value. Save the change and exit the editor.

browse-proj2-9.png

  1. When we apply this view filter, we are prompted to specify the sample name for the sample result we are after. Simply type the name of the sample and click OK.

browse-proj2-10.png

The results for the sample are displayed.

browse-proj2-11.png

Every time you click the Update button, you are prompted to specify the sample name for the next result you are after. This way one view filter does the work of many.

One final note: Each table in Browse Project has its own set of unique filters. Why? Because each table displays different information, such as raw data, results, or methods.

Finally, the View Filters tab displays a list of all of the view filters in the project and indicates which table each one belongs to.

 

 