What are the spare parts for the LAC/E32? - WKB81054
ENVIRONMENT
- Empower LAC/E32
- UNIFI LND
ANSWER
Instruments or part numbers with a line through them are obsolete.
Instruments or part numbers that are italicized are discontinued.
Config 13 | Config 14 | Config 15 | LND CFG 1 | LND CFG 2 | |||||
---|---|---|---|---|---|---|---|---|---|
LACE32 repair parts |
Waters Part Number | Waters Part Number | Waters Part Number | Waters Part Number | Waters Part Number | Waters Part Number | Waters Part Number | Waters Part Number | Waters Part Number |
Hard Drive, 160 GB (SATA) | 700000985 | 66800381 | N/A | N/A | N/A | ||||
Hard Drive, 250 GB (SATA) | 700008988 | 700008988 | 700008988 | 668000429, 668000429JA (700008988) | 700005890 | N/A | 700009227 | ||
Hard Drive, 320 GB (SATA) | 700010341 | ||||||||
Hard Drive, 1 TB (SATA) | 700010046 | ||||||||
Power Supply | 700003090 | 700003090 | 700003090 | 700003090 | 700003090 | 700005891 | 700009909 | 700009410 | 700010344 |
CD Drive, 52X | 700002834 | 700002834 | N/A | N/A | N/A | N/A | |||
Memory, 256 MB | 700002423 | N/A | N/A | N/A | N/A | N/A | |||
Memory, 512 MB | 668000359 | N/A | N/A | N/A | N/A | ||||
Memory, 1024 MB | 668000362 | 668000365 | 668000366 | N/A | N/A | N/A | N/A | ||
Memory, 2024 MB | N/A | N/A | N/A | 700003807 | 668000376 (2x1GB) | 700005889 | N/A | 700005889 | |
Memory, 4 GB | N/A | N/A | N/A | N/A | N/A | N/A | 700010045 | 700010045 | |
Motherboard* | N/A | 700002832 | 668000375 | 700005892 | 700010048 | 700009411 | 700010343 | ||
DVD drive | N/A | N/A | 700002835 | 668000377 | 700005894 | 700010047 | 700010342 | ||
Thermal Sensor/mount |
700008905 700005984 |
700008905 700005984 |
|||||||
Fan | 700005893 | 700005893 | |||||||
Network card | 700003809 |
668000378 668000379 |
668000378 668000379 |
668000462 | 668000417 | ||||
Restore disks |
667002920 (XP)
|
667002924 (W2K)
667002926 (XP)
|
667002928 (W2K)
667002930 (XP)
667003161 (XP)
|
667003394 (XP) 667003395 (XP) |
667003855 (XP) 667004310 (W7)
667004310JA (W7) 667004612 (W7) 667004612JA (W7) |
667004729 (W7) 667004729JA (W7) 667004728 (XP)
|
667004957 667004957JA |
||
LACE32 / LND part numbers |
668000260(WNT) 668000260JA (WNT) 668000263(W2K) 668000263JA (W2K) 668000266(WXP) 668000266JA (WXP) 668000266KO (WXP) 668000266ZH (WXP) |
668000260(WNT) 668000260JA (WNT) 668000263(W2K) 668000263JA (W2K) 668000266(WXP) 668000266JA (WXP) 668000266KO (WXP) 668000266ZH (WXP) |
668000302(W2K) 668000302JA (W2K) 668000303(WXP) 668000303JA (WXP) 668000304(W2K) 668000304JA (W2K) 668000305(WXP) 668000305JA (WXP) 668000307(W2K) 668000307JA (W2K) 668000309(WXP) 668000309JA (WXP) 668000326(WXP) 668000326JA (WXP) 668000313(W2K) 668000313JA (W2K) 668000314(WXP) 668000314JA (WXP) 668000315(W2K) 668000315JA (W2K) 668000316(WXP) 668000316JA (WXP) |
668000350(WXP) 668000350JA (WXP) 668000351(WXP) 668000351JA (WXP) 668000349(WXP) 668000349JA (WXP) 668000354(WXP) 668000354JA (WXP) 668000352(WXP) 668000352JA (WXP) 668000353(WXP) 668000353JA (WXP) |
668000370 668000371 668000372 668000373 668000374 |
668000411 668000422 (XP) 668000422JA (XP) 668000423 (W7) 668000423JA (W7) |
668000441 668000443 (W7) 668000443JA (W7) |
668000414 668000414JA 668000414ZH |
668000444 668000444CN 668000444JA |
Serial number range | Serial numbers lower than C04L32196W are Config 9. | Serial numbers higher than C04L32196W are Config 10. | Last Manufactured Serial Number: F07L32046W | First Manufactured Serial Number: F07L32052W | First Manufactured Serial Number: B14L32043W B14L32047W B14L32051W | First Manufactured Serial Number: M11LND001W | First Manufactured Serial Number: J14LND001W | ||
First sale dates | 01 June, 2003 | 01 March, 2004 | 01 November, 2005 | 01 June, 2007 | 01 April, 2009 | 01 March, 2012 | 01 February, 2014 | 01 December, 2011 | 01 September, 2014 |
*NOTE: Config 14 is Milford Repair Center only.
ADDITIONAL INFORMATION
id81054, EMP2LIC, EMP2OPT, EMP2SW, EMP3GC, EMP3LIC, EMP3OPT, EMP3SW, EMPGC, EMPGPC, EMPLIC, EMPOWER2, EMPOWER3, EMPSW, SUP, SUPUNIFI, UNIFISVR, UNIFISW18, UNIFLND, UNIFLND02, UNIFLND3, UNIFOPT, UNIFQLIC, UNIFSW17, UNIFSW18, UNIFSW19, UNIFWGLIC, UNIFWKLIC