What are the MassLynx instrument compatibilities with Waters Driver Pack 2022 Release 1? - WKB228910
Article number: 228910
ENVIRONMENT
- MassLynx
- ACQUITY Arc
- ACQUITY UPLC
- ACQUITY UPLC H-Class
- ACQUITY UPLC H-Class Bio
- ACQUITY UPLC I-Class
- ACQUITY UPLC H-Class PLUS
- ACQUITY UPLC H-Class PLUS Bio
- ACQUITY UPLC I-Class PLUS
- ACQUITY UPLC M-Class
- nanoACQUITY UPLC
- ACQUITY Premier
- Arc HPLC
- Arc Premier
ANSWER
The following table lists the supported mass spectrometers and the associated SCNs. Waters expects that other, untested mass spectrometers are compatible, meaning they will function as expected if installed with the appropriate SCN.
MassLynx Instrument Compatibility with DP 2022 R1 |
||||
|---|---|---|---|---|
| MassLynx | HPLC and UHPLC Systems (9,000 PSI) | |||
| SCN | MS | Arc Premier Binary | Arc Premier and Arc/Arc Bio Quaternary Systems | Arc HPLC |
| 993 | QDa | Yes | Yes | Yes |
| 1035 | SQD2 | Yes | Yes | Yes |
| 1035 | Xevo TQD | Yes | Yes | No |
| 1035 | Xevo TQ-S u cronos | Yes | Yes | No |
| 1035 | Xevo TQ-S micro | Yes | Yes | No |
| 1035 | Xevo TQ-XS | Yes | Yes | No |
| 1024 | Xevo TQ -Absolute | Yes | Yes | No |
| 1035 | Xevo TQ-S | Yes | Yes | No |
| 1028 | Synapt XS | Compatible | Compatible | No |
| 1029 | Xevo G2-XS Qtof/Tof | Compatible | Compatible | No |
| NA | SS Cyclic IMS | Compatible | Compatible | No |
| NA | SS MRT | Compatible | Compatible | No |
| MassLynx | UPLC Systems (15,000 PSI) | UPLC Systems (18,000 PSI) |
||
| SCN | MS | ACQUITY Premier Binary and Quaternary |
ACQUITY H-Class/H-Class Bio Binary and Quaternary | ACQUITY I-Class Systems |
| 993 | QDa | Yes | Yes | Yes |
| 1035 | SQD2 | Yes | Yes | Yes |
| 1035 | Xevo TQD | Yes | Yes | Yes |
| 1035 | Xevo TQ-S u cronos | Yes | Yes | Yes |
| 1035 | Xevo TQ-S micro | Yes | Yes | Yes |
| 1035 | Xevo TQ-XS | Yes | Yes | Yes |
| 1024 | Xevo TQ -Absolute | Yes | Yes | Yes |
| 1035 | Xevo TQ-S | Yes | Yes | Yes |
| 1028 | Synapt XS | Yes | Yes | Yes |
| 1029 | Xevo G2-XS Qtof/Tof | Yes | Yes | Yes |
| NA | SS Cyclic IMS | Compatible | Compatible | Compatible |
| NA | SS MRT | Compatible | Compatible | Compatible |
| MassLynx | Specialty Systems | |||
| SCN | MS | ACQUITY UPC2 Systems | MicroBSM DESI | ACQUITY M-Class Systems |
| 993 | QDa | Compatible | Compatible | Compatible |
| 1035 | SQD2 | Compatible | Compatible | Compatible |
| 1035 | Xevo TQD | Compatible | Compatible | Compatible |
| 1035 | Xevo TQ-S u cronos | Compatible | Compatible | Compatible |
| 1035 | Xevo TQ-S micro | Compatible | Compatible | Compatible |
| 1035 | Xevo TQ-XS | Compatible | Compatible | Compatible |
| 1024 | Xevo TQ -Absolute | Compatible | Compatible | Compatible |
| 1035 | Xevo TQ-S | Compatible | Compatible | Compatible |
| 1028 | Synapt XS | Compatible | Compatible | Compatible |
| 1029 | Xevo G2-XS Qtof/Tof | Compatible | Compatible | Compatible |
| NA | SS Cyclic IMS | Compatible | Compatible | Compatible |
| NA | SS MRT | Compatible | Yes | Yes |
| MassLynx | Legacy | |||
| SCN | MS | ACQUITY UPLC Systems | nanoACQUITY UPLC Systems | |
| 993 | QDa | Compatible | Compatible | |
| 1035 | SQD2 | Compatible | Compatible | |
| 1035 | Xevo TQD | Compatible | Yes | |
| 1035 | Xevo TQ-S u cronos | Compatible | Yes | |
| 1035 | Xevo TQ-S micro | Compatible | Yes | |
| 1035 | Xevo TQ-XS | Compatible | Yes | |
| 1024 | Xevo TQ -Absolute | Compatible | Yes | |
| 1035 | Xevo TQ-S | Compatible | Yes | |
| 1028 | Synapt XS | Compatible | Yes | |
| 1029 | Xevo G2-XS Qtof/Tof | Compatible | Yes | |
| NA | SS Cyclic IMS | Compatible | Compatible | |
| NA | SS MRT | Compatible | Compatible | |
| Definitions | In development | Third-party vendor has agreed to support, but development is not complete | |||
| Compatible | Expected to work, but not tested | ||||
| Yes | Supported, by evaluation or formally risk-assessed for support | ||||
| No | No formal evaluation or formal risk assessment for support | ||||
NOTE: Unlisted systems imply outside acquisition control agreement. Systems and their accessories, such as APC and PATROL, are typically excluded.