Low sensitivity or no peaks at certain points - WKB101611

Article number: 101611

SYMPTOMS

  • Low sensitivity
  • No peaks
  • Incorrect retention time
  • Strange baseline

ENVIRONMENT

  • Alliance HPLC System
  • 2695 Separations Module
  • 2695D Dissolution Separations Module
  • 2795 Separations Module
  • Alliance Series Column Heater
  • Alliance Series Column Heater/Cooler
  • ACQUITY APC
  • ACQUITY APC Isocratic Solvent Manager
  • ACQUITY APC Sample Manager - FTN
  • ACQUITY Arc
  • ACQUITY Arc Sample Manager FTN-R
  • ACQUITY UPLC
  • ACQUITY UPLC BSM (example, use other modules as needed)
  • ACQUITY UPLC Column Manager
  • ACQUITY UPLC H-Class
  • ACQUITY UPLC H-Class Bio
  • ACQUITY UPLC H-Class Quaternary Solvent Manager (QSM)
  • ACQUITY UPLC I-Class
  • ACQUITY UPLC H-Class PLUS
  • ACQUITY UPLC H-Class PLUS Bio
  • ACQUITY UPLC I-Class PLUS
  • ACQUITY UPLC M-Class
  • nanoACQUITY UPLC
  • PATROL UPLC Process Analysis System
  • ACQUITY UPLC Process Sample Manager
  • ACQUITY UPLC Column Heater
  • ACQUITY UPLC PDA Detector
  • ACQUITY UPLC Sample Manager 
  • ACQUITY UPLC Sample Manager - Flow Through Needle PLUS (SM-FTN PLUS)
  • ACQUITY UPLC Sample Organizer
  • ACQUITY UPLC Tunable UV Detector
  • ACQUITY UPLC FLR Detector
  • ACQUITY UPLC RI Detector
  • ACQUITY UPLC Online SPE Man
  • 510 HPLC pump
  • 515 HPLC Pump
  • 600 MultiSolvent Delivery Pump
  • 717plus Autosampler
  • 1500 Series Column Heater
  • 1515 Isocratic HPLC Pump
  • 1525 Binary HPLC Pump
  • 1525 Micro Binary HPLC Pump
  • 2707 Sample Manager
  • 2777 Sample Manager
  • e-SAT/IN Module
  • Waters SAT/IN Module
  • Bus SAT/IN Module
  • 2410 Differential Refractometer
  • 432 Conductivity Detector
  • 2432 Conductivity Detector
  • 2414 Refractive Index Detector
  • 2420 Evaporative Light Scattering Detector
  • 2424 Evaporative Light Scattering Detector
  • 2465 Electrochemical Detector
  • 2475 Multi-Wavelength Fluorescence Detector
  • 2487 Dual-Wavelength Absorbance Detector
  • 2488 Multichannel Absorbance Detector
  • 2489 UV/Vis Detector
  • 2996 PDA Detector
  • 2998 Photodiode Array Detector
  • ACQUITY UPLC Tunable UV Detector
  • ACQUITY UPLC PDA Detector
  • ACQUITY UPLC PDA eλ Detector
  • ACQUITY UPLC FLR Detector
  • ACQUITY UPLC ELS Detector
  • ACQUITY QDa Mass Detector
  • CTC PAL Autosampler
  • Agilent 1260 Infinity
    Refractive Index Detector
  • Agilent 7890 GC
  • Agilent 7697A Headspace
  • Agilent 6890 GC
  • Agilent 6850 GC
  • AutoSpec Premier
  • GCT
  • GCT Premier
  • Quattro Micro GC
  • Atmospheric Pressure GC
  • Quattro Premier
  • Quattro Premier XE
  • Quattro LC
  • Quattro LCZ
  • Quattro micro API
  • Quattro Ultima
  • 3100 Mass Detector
  • ACQUITY SQD system
  • SQ Detector
  • ACQUITY TQD system
  • TQ Detector
  • SQ Detector 2
  • Xevo TQ MS
  • Xevo TQD
  • Xevo TQ-GC
  • Xevo TQ-S
  • Xevo TQ-S cronos
  • Xevo TQ-S micro
  • Xevo TQ-XS
  • ZQ 2000
  • ZQ 4000
  • ZMD

 

CAUSE

Old or wrong chemistry

FIX or WORKAROUND

  1. Use a freshly prepared sample.
  2. Use a fresh column.
  3. Use a fresh precolumn / filter.
  4. Use freshly prepared mobile phases and wash solutions.
  5. Use the correct Method and solvents.

ADDITIONAL INFORMATION

Always double-check; never trust labels.

Not able to find a solution? Click here to request help.