What are considered as Empower project modifications in terms of SDMS archival and SDMS Data Management? - WKB278233

Article number: 278233

ENVIRONMENT

  • NuGenesis SDMS
  • Empower (all versions)

ANSWER

SDMS Archival and Data Management consider only three actions as project modifications in Empower:

  • Change in Last Acquisition Date, as a result of acquiring new data to the project 
  • Change in Last Processed Date, as a result of reprocessing data within the Empower project
  • A change in Signature information, as a result of the Signing Off of Empower Data

 

NOTE: No other action is considered a project modification. Empower projects that have not been modified in one of the three ways listed will not be re-archived and, if using SDMS Data Management, would subsequently be deleted from the Empower database.  