Does Waters still sell part number PSL618011 - Double SLIP-FREE Connector, 20cm, 0.010 inch ID (or any other SLIP-FREE Connectors)? - WKB58218

Article number: 58218

ENVIRONMENT

  • Connectors
  • SLIP-FREE Connectors
  • Fittings

ANSWER

No.

ADDITIONAL INFORMATION

Waters discontinued selling SLIP-FREE connectors in 2018.

Connector options may include the following:

HPLC:

WAT084080 - ASSEMBLY, TUBE JOINING - Stainless steel "U" shape tubing with pre-installed compression screws and ferrules. The ferrules are permanently seated to Waters depth setting upon receipt. Compatible with most traditional Waters HPLC Columns. This tubing's ID is 0.009 inch and OD is 1/16 inch.

clipboard_ea092e1548d386955800ebcb83feb1af6.png

WAT022681 - RIGID CONNECTOR PKG - This is a straight stainless steel connector with pre-installed compression screws and ferrules. The ferrules are permanently seated to Waters depth setting upon receipt. Compatible with most traditional Waters HPLC Columns. This tubing's ID is 0.005 inch and OD is 1/16 inch.

clipboard_e26276f4a8d14b35834c1cae7e40ccc0c.png

HPLC or UPLC:

U-Shaped:

700009535 - ASSY, TUBE, .004 ID, COL. CONN., "U"

clipboard_eeeb5cc0af64a9ec53f3f2608578770b9.png

Ferrules are not staked on tubing upon receipt. 

The two-piece ferrule is permanently seated upon installation once the fitting is tightened into the column.

Offset U-Shape:

700009534 - ASSY,TUBE,.004 ID,COL. CONN., OFFSET "U"

clipboard_e3b9252defa5d346ed8266b1132a7117e.png

Ferrules are not staked on tubing upon receipt. 

The two-piece ferrule is permanently seated upon installation once the fitting is tightened into the column.

Straight:

700009524 - ASSY, TUBE, .005 ID, COL. CONN., INLINE

clipboard_ee54598ff1e913c632c55ab6518a8c09f.png

Ferrules are lightly staked on tubing upon receipt.

The two-piece ferrule is permanently seated upon installation once the fitting is tightened into the column.

186006613 - .005"x1.75" UPLC Connection Tubing, 2 PK

clipboard_e69accf64ffcae7fcd062f4a920f78805.png

Ferrules are lightly staked on tubing upon receipt.

The two-piece ferrule is permanently seated upon installation once the fitting is tightened into the column.

OPTIONAL: The following fitting kit and related appropriate tubing requires tubing cutter to cut proper length to connect to inlet of column:

For UPLC:

For UPLC column inlet connection:

700003139 -  KIT, FITTING, REUSE 10-32, FINGER TIGHT (Slips onto tubing with an OD of 1/16 inch).

clipboard_eba5fcb73e84801645abb2f91a56e668c.png

For UPLC column outlet connection:

700004841 -  FITTING, 10-32, ONE-PIECE, MODIFIED 10PK

clipboard_e4f69911f27d8ce257e47c685c2744b34.png

For HPLC:

WAT241039 - TUBE,SS .062X.005X120"

clipboard_ed8d58671908d55bdded6a63499865bb9.png

OR

WAT026973 - TUBE SS .062X.009X10FT

clipboard_e4cc82547e74914817e9a1caca7a2e79d.png

WAT022384 1/16" OD SS TUBING CUTTER +3 Blades

clipboard_e196bf4dfd834e51e3354f20e2562dd93.png

For inlet or outlet of HPLC Columns (Stainless Steel):

WAT005070 - COMP SCREW SS 10/PK

clipboard_ed79c3116785c5712f8327920cb40036f.png

WAT005063 - FERRULE 01 ANNEAL SS 10/PK

clipboard_ef75fa31536f45f81d5a7c7bf32e6f4ef.png

For inlet or outlet of HPLC Columns (PEEK):

186008714 - PEEK Finger-tight Fitting, 10-32, 1 ea

clipboard_e74ad8ed3277a540b1399f90a241d6c19.png

For outlet of UPLC columns:

Related videos: 

Column Videos  (Shows fittings videos, how to connect columns)

Not able to find a solution? Click here to request help.