What is a good column choice for the analysis of water-soluble vitamins? - WKB28185
ENVIRONMENT
- Water-soluble vitamins
- Polar compound retention
- Ascorbic Acid
- Nicotinamide
- Pyridoxal
- Riboflavin
- Nicotinic acid
- Thiamine
- Ascorbic acid
- B12
- Folic Acid
- Vitamin C
- Atlantis Premier BEH C18 AX
- MaxPeak
- High Performance Surfaces (HPS)
- High Strength SIlica (HSS)
- T3
- Bridged Ethylene Hybrid (BEH)
- High Strength Silica (HSS)
- Column
- CORTECS
- Hydrophilic Interaction Chromatography (HILIC)
ANSWER
Mixed-Mode: (Reversed-Phase with Weak Anion Exchange)
- Atlantis Premier BEH C18 AX (1.7um, 2.5um and 5um)1
Reversed-Phase:
- ACQUITY Premier HSS T3 (1.8um)2
- ACQUITY UPLC HSS T3 (1.8um)
- CORTECS Premier T3 (1.6um & 2.7um, solid core particles)1
- CORTECS T3 (1.6um & 2.7um, solid core particles)
- XSelect Premier HSS T3 (2.5um)1
- XSelect HSS T3 (2.5um, 3.5um, 5um & 10um)
- Atlantis T3 (3um, 5um & 10um)
- Atlantis dC18 (3um, 5um & 10um)
HILIC: (Hydrophilic Interaction Chromatography)
- Atlantis Premier BEH Z-HILIC (1.7um, 2.5um and 5um)1
- ACQUITY Premier BEH Amide (1.7um)2
- ACQUITY UPLC BEH Amide (1.7um)
- XBridge Premier BEH Amide (2.5um)1
- XBridge BEH Amide (2.5um, 3.5um, 5um & 10um)
1. Packed in MaxPeak Premier hardware in 2.1mm I.D. and 4.6mm I.D.
2. Packed in MaxPeak Premier hardware in 2.1mm I.D.
MaxPeak HPS (High Performance Surfaces) makes the stainless steel frits and column surfaces inert so that acidic analytes will not adsorb to the positive charges of the stainless steel as samples contact the stainless steel surfaces inside the column.
ADDITIONAL INFORMATION
A Rapid and Simple Clinical Research Method for Vitamin C in Serum by UPLC-QDa (uses Atlantis Premier BEH C18 AX column)
ACQUITY UPLC BEH Amide Applications Notebook (includes example of water-soluble vitamin separation)
XBridge Amide Applications Notebook (includes example of water-soluble vitamin separation)
Direct Scaling of HPLC Separations to UPLC Technology for the Analysis of Polar Compounds (poster – includes HSS T3 and water-soluble vitamins)
Atlantis dC18 and HILIC Applications Notebook (includes example of water-soluble vitamin separation)
MaxPeak Premier Columns Web Page
MaxPeak Premier Columns with MaxPeak High Performance Surfaces - Ordering Information
MaxPeak Premier | Non-Specific Adsorption – Infographic
MaxPeak Premier Columns for Small Molecule Analysis – Infographic
Atlantis Premier BEH Z-HILIC Columns Infographic
Atlantis Premier BEH C18 AX Columns Infographic
Low Adsorption HPLC Columns Based on MaxPeak High Performance Surfaces – White Paper