What are the differences between part numbers 176001279 (UPLC AAA Applications Kit), 176002983 (UPLC AAA H-Class Applications Kit), and 176001235 (AccQ-Tag Ultra Chemistry Kit)? - WKB26529

Article number: 26529

ENVIRONMENT

  • AccQ-Tag Ultra
  • Amino acid analysis 
  • AAA
  • kit contents
  • refill
  • add on
  • ACQUITY UPLC
  • H-Class
  • components of
  • included parts

ANSWER

176001279 - UPLC AAA Applications Kit contains all items needed for an existing ACQUITY UPLC Binary System to run the AccQ.Tag Ultra method. 

176002983 - UPLC AAA H-Class Applications Kit contains all items needed for an existing ACQUITY UPLC H-Class or ACQUITY UPLC H-Class Bio System to run the AccQ.Tag Ultra method. 

176001235 - AccQ-Tag Ultra Chemistry Kit contains all consumables needed to perform the AccQ.Tag Ultra method on any of the following systems that have already been configured to run the official AccQ.Tag Ultra method: ACQUITY UPLC Binary System, ACQUITY UPLC H-Class System, or ACQUITY UPLC H-Class Bio System. 

ADDITIONAL INFORMATION

Biomolecule Purification, Characterization, and Analyses Catalog

176001279 - UPLC AAA Applications Kit contains:

Amino Acid Standard, Hydrolysate 10 × 1 mL

Sample Tubes 4 × 72/pk

Total Recovery Vials with Caps 3 × 100/pk

Column Stabilizer Kit, 150 mm

AccQ•Tag Ultra Derivatization Kit

AccQ•Tag Ultra C18 Column, 1.7 μm, 2.1 × 100 mm

AccQ•Tag Ultra Eluent A, Concentrate 950 mL

AccQ•Tag Ultra Eluent B 950 mL

Tube Inlet .0025 I.D. PEEK Nut PDA Assembly

2 μL Sample Loop

Column In-line Filter Kit

UPLC AAA Solution Information Set

UPLC AAA Application Solution Startup Tests

Cert., AAA Application and Familiarization

176002983 - UPLC AAA H-Class Applications Kit contains:

AccQ•Tag Ultra Derivatization Kit, 250 Analyses

AccQ•Tag Ultra C18 Column, 1.7 μm, 2.1 × 100 mm

AccQ•Tag Ultra Eluent A, Concentrate 950 mL

AccQ•Tag Ultra Eluent B 950 mL

Amino Acid Standard, Hydrolysate 10 × 1 mL

Total Recovery Vials 3 × 100 vials/pk

Tube Inlet 0.0025 I.D. PEEK Nut PDA Assembly

Column In-line Filter Kit

UPLC AAA H-Class Solution Information Set

AAA Application and Familiarization Service

176001235 - AccQ-Tag Ultra Chemistry Kit contains:

AccQ•Tag Ultra Derivatization Kit, 250 Analyses  **

AccQ•Tag Ultra C18 Column, 1.7 μm, 2.1 × 100 mm

AccQ•Tag Ultra Eluent A, Concentrate 950 mL

AccQ•Tag Ultra Eluent B 950 mL

Amino Acid Standard, Hydrolysate 10 × 1 mL ***

Sample Tubes 4 × 72/pk

Total Recovery Vials with Caps 3 × 100/pk

**186003836 - AccQ•Tag Ultra Derivatization Kit, 250 Analyses

AccQ•Tag Ultra Borate Buffer 5 × 6 mL

AccQ•Tag Ultra Derivatization Reagent Powder 5 × 3 mg

AccQ•Tag Ultra Reagent Diluent 5 × 4 mL

***WAT088122 - Amino Acid Standard, Hydrolysate 10 × 1 mL

A standard mixture containing 18 amino acids (17 hydrolysate amino acids each at 2.5 mM and cystine at 1.25 mM)

Not able to find a solution? Click here to request help.